Gardner bender gdt 11 manual. GB Instruments Multimeter Instructions 2019-03-26

Gardner bender gdt 11 manual Rating: 8,5/10 804 reviews

Gardner Bender 3

gardner bender gdt 11 manual

Touch the tip of the black meter probe to the negative battery clip wire. Lorsque l'appareil n'est pas utilisé, s'assurer de l'éteindre pour empêcher la décharge de la pile. Common Input Jack Toma de entrada común Prise d'entrée commune 9. Para limpiar el alojamiento use un paño húmedo con una mínima cantidad de jabón suave. Gdt 311 Gardner Bender User Manual can be very useful guide, and gdt 311 gardner bender user manual play an important role in your products. Rotate the dial to the small white icon on the multimeter that looks like sound waves expanding outward if you desire to test a wire to make sure it isn't broken. Les appareils endommagés doivent être mis au rebut.

Next

GB Instruments Multimeter Instructions

gardner bender gdt 11 manual

Este medidor es un dispositivo medidor sensible y debe tratarse con la misma consideración que otros eléctricos y electrónicos. Wear rubber soled boots or shoes. Advice for recycling your old appliance If your newly purchased appliance replaces an older appliance, you must consider a few aspects. Lastmanuals, for instance, does not offer a translation service. Touch the sharp tip of the black test probe to one side of the component or circuit and the sharp tip of the red test probe to the other side of the component or circuit. A Gardner Bender multimeter is used most effectively if the voltage, current or resistance of the circuit or component is known before testing.

Next

GB INSTRUMENTS GDT

gardner bender gdt 11 manual

The quantity and the rapidity of ice buildup depends on the ambient conditions and on the frequency of the door opening. In this case, rotate the selector knob so the white indicator on the dial is pointing to 200. Nunca mida la corriente cuando el selector esté colocado en la escala de resistencia. When measuring outlets the specially spaced lead holders allow for single one hand testing 3. Appliquer d'abord le fil noir d'essai commun sur la source c. Lea el valor de la medida mostrada.

Next

GB INSTRUMENTS GDT

gardner bender gdt 11 manual

Le multimètre doit indiquer 120 V c. Read the value of the measurement displayed. Warning Avoid touching the metal probe tips when measuring voltages greater that 50V; high voltages pose a shock hazard. A 160 page guide to using analog and digital multitesters. Touch the test leads to the circuit under test.

Next

GB Instruments Multimeter Instructions

gardner bender gdt 11 manual

. Touch the metal tip of the red meter probe to the positive wire of the battery clip; usually this is the red wire. Requires 9V battery - not included. The 14 position manual ranging smooth rotary dial helps achieve precise and accurate readings and the low battery indicator gives a warning when the batteries need to be replaced. Touch the tip of the black probe to the negative wire, which is black.

Next

Test, Measurement & Inspection

gardner bender gdt 11 manual

Before defrosting, adjust the thermostat knob to a higher position so that the food stores more cold. La indicación de un diodo en buen estado es una lectura de resistencia baja cuando Corte el suministro eléctrico al interruptor. Éviter de placer le multimètre dans des endroits où la vibration, les poussières ou la saleté sont présentes. Remarque : Ne pas utiliser de piles rechargeables ou au lithium avec cet appareil 4. Lea el valor de la medida mostrada. Specifications Replace worn test leads. Use the 2000K range when testing for resistance values in electronic components such as resistors and potentiometer.

Next

Reading : Gdt 311 Gardner Bender User Manual

gardner bender gdt 11 manual

Retirer les vis du couvercle arrière de l'appareil puis retirer soigneusement le couvercle. No apriete demasiado los tornillos porque puede romper los roscados en el alojamiento del probador. Caution: When changing the battery, disconnect the test leads from the circuit completely. Toque el circuito a prueba con los conductores de prueba. Use botas o zapatos con suelas de goma. Reemplace por una batería fresca de 9 voltios. If you know the voltage to be tested should be between 20 and 200 volts, set the meter to the highest number.

Next

Gardner Bender GDT

gardner bender gdt 11 manual

Copyrights © 2019 All rights reserved. Si la valeur du composant correspond à une autre plage que celle utilisée, remettre le sélecteur au réglage approprié pour obtenir une lecture plus précise. Test voltage with a Gardner Bender multimeter by selecting which type of voltage is to be measured. Pour des mesures plus précises, utiliser la gamme la plus basse sans pour autant dépasser la valeur. You should see a reading of about 90 milliamps or.

Next

Gardner Bender 3

gardner bender gdt 11 manual

N No otta a:: No use baterías recargables ni de litio en esta unidad. The presence of this ice build-up makes impossible to close the door correctly. The meter should measure roughly 9 volts. Los medidores dañados deben descartarse. Do not use test leads with broken or tattered insulation. Para obtener mediciones más exactas use el rango más bajo posible sin exceder el valor. Régler le sélecteur à la plage de tension c.

Next